Form factor | 2U rack server |
CPU | |
Chipset | Intel C612 |
RAID support | The RH2288 V3 supports the following models of RAID controller cards: SR320 or SR420: Uses the LSI SAS2208 chip. Supports RAID 0, 1, 10, 5, 50, 6, and 60. Supports a supercapacitor for power failure protection.
SR120: Uses the LSI SAS2308 chip. Supports RAID 0, 1, 1E, and 10. Does not support power failure protection.
SR130: Uses the LSI SAS3008 chip. Supports RAID 0, 1, 10, and 1E. Does not support power failure protection.
SR430C: Uses the LSI SAS3108 chip. Supports RAID 0, 1, 10, 5, 50, 6, and 60. Supports a cache of 1 GB or 2 GB. Supports a supercapacitor for power failure protection.
SP435: Uses the PM8060 chip. Supports RAID 0, 1, 10, 5, 50, 6, and 60. Supports a supercapacitor for power failure protection.
SR135: Uses the PM8068 chip. Supports RAID 0, 1, 10, and 5. Does not support power failure protection.
These RAID controller cards support RAID level migration and drive roaming. NOTE:The SP435 (PM8060) controller card is a standard PCIe card, which can be installed in a PCIe slot. Multiple RAID controller cards configuration specifications are provided. For details, see Intelligent Computing Compatibility Checker.
|
Memory | Up to 16 DDR4 DIMM slots (8 DIMMs per CPU) for installing either RDIMMs or LRDIMMs 16 x 32 GB RDIMMs for two CPUs, with a maximum memory capacity of 512 GB 16 x 128 GB LRDIMMs for two CPUs, with a maximum memory capacity of 2048 GB Maximum memory speed: 2400 MT/s Memory protection technologies: Error Checking and Correction (ECC), memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep
NOTE:DIMMs of different types (RDIMMs and LRDIMMs) and specifications (such as the capacity, bit width, rank, and height) cannot be installed in one server. That is, all DIMMs in one server must have the same BOM number. To query the BOM numbers of DIMMs, use the Intelligent Computing Compatibility Checker. |
Storage | Multiple hard disk configuration specifications are provided. For details, see Introduction. Hard disks are hot-swappable. The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID level migration, drive roaming, self-diagnosis, and web-based remote configuration. The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 2 GB cache) to improve hard disk storage performance and ensure user data security. The RAID controller card does not occupy a standard PCIe slot, improving system scalability.
NOTE:If the server is equipped with 12 hard disks at the front, you can install two or four 2.5-inch SAS HDDs, SATA HDDs, and SSDs or 3.5-inch SAS HDDs and SATA HDDs at the rear of the server to expand the local storage capacity. If the server is equipped with 25 hard disks at the front, you can install three 2.5-inch SAS HDDs, SATA HDDs, and SSDs at the rear of the server to expand the local storage capacity. If SATADOM SoftRAID is used when NVMe PCIe SSDs are configured, only the Legacy mode can be selected for the BIOS.
|
Network port | Six types of FlexIO cards are supported, which provide the following network ports: Two GE electrical ports, supporting NC-SI, Wake on LAN (WOL), and Preboot Execution Environment (PXE) Four GE electrical ports, supporting NC-SI, WOL, and PXE Two 10GE optical ports, supporting NC-SI and PXE Two 10GE electrical ports, supporting NC-SI, WOL, and PXE Two 56G IB optical ports. The FlexIO card does not support NC-SI, WOL, or PXE. One 56G IB optical port. The FlexIO card does not support NC-SI, WOL, or PXE.
|
PCIe slot | The RH2288 V3 provides one PCIe 3.0 x8 slot dedicated for a RAID controller card and five standard PCIe 3.0 x8 slots. The specifications for the five standard PCIe slots are described as follows: One full-height full-length standard PCIe 3.0 x16 slot (bus width: PCIe 3.0 x8), one full-height full-length standard PCIe 3.0 x8 slot, and one full-height half-length standard PCIe 3.0 x8 slot on I/O module 2 (Signals of the PCIe slots on I/O module 2 come from CPU 2.) Two half-height half-length standard PCIe 3.0 x8 slots on the mainboard (PCIe slot signals come from CPU 1.)
PCIe slots on an I/O module can house a maximum of two Huawei ES3000 V2 SSDs to improve I/O performance for search, cache, and download services. PCIe slots can house K2000 and NVS 315 GPUs.
NOTE:Specifications of the rear hard disk module: Specifications of the I/O module: One full-height full-length standard PCIe 3.0 x16 slot (bus width: PCIe 3.0 x8), one full-height full-length standard PCIe 3.0 x8 slot, and one full-height half-length standard PCIe 3.0 x8 slot Two full-height full-length standard PCIe 3.0 x16 slots (bus width of one slot: PCIe 3.0 x8) Two 2.5-inch hard disk slots The fifth-generation SSD cards must be installed in the two slots on a riser card. A server supports a maximum of two fifth-generation SSD cards.
|
Port | Two USB 2.0 ports and one DB15 VGA port on the front panel of the server with up to eight 2.5-inch or ten 3.5-inch hard disks Two USB 3.0 ports, one DB15 VGA port, one DB9 serial port, and one RJ45 system management port on the rear panel One internal USB 3.0 port, one internal dual-SD port, and two internal miniSSDs (SATADOMs) for installing an OS or prebooting an installation program
NOTE:The internal USB port cannot be used for installing a Windows OS. The server with two internal miniSSDs (SATADOMs) and SoftRAID does not support the installation of a virtualization OS. Use the Intelligent Computing Compatibility Checker to check OSs that can be installed. |
Fan module | Four hot-swappable fan modules, allowing one-fan failures |
PSU | Two hot-swappable PSUs in redundancy mode: 460 W AC Platinum PSU, supporting 240 V HVDC 750 W AC Platinum PSU, supporting 240 V HVDC 750 W AC Titanium PSU 1200 W PSU, supporting 380 V HVDC 800 W PSU, supporting –48 V DC or –60 V DC
|
System management | UEFI Huawei iBMC Uses an independent port. Supports Simple Network Management Protocol (SNMP) and Intelligent Platform Management Interface (IPMI). Provides the GUI, virtual KVM, virtual media, Serial Over LAN (SOL), smart power control, remote control, and hardware monitoring features.
NC-SI Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios
|
Security | |
GPU | Integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors. NOTE:After a dedicated graphics card driver is installed, only Windows Server 2012, Windows Server 2012 R2, Windows Server 2016 can support the resolution of 1920 pixels x 1200 pixels while other OSs only support the maximum resolution supported by the built-in drivers. If the resolution is greater than 1024 x 768, the display effect may be affected.
|