ລະບົບແມ່ແຈກ

Huawei RH2288 V3 2U dual-socket rack server

The RH2288 V3 (marked as H22M-03 on the nameplate) is a 2U dual-socket rack server launched by Huawei to meet customer requirements for the Internet, Internet data center (IDC), cloud computing, enter

The RH2288 V3 (marked as H22M-03 on the nameplate) is a 2U dual-socket rack server launched by Huawei to meet customer requirements for the Internet, Internet data center (IDC), cloud computing, enterprise market applications, and telecom service applications.

The RH2288 V3 features high-performance computing, large storage capacity, low power consumption, and high scalability and reliability. It supports virtualization, and is easy to manage and deploy. It is ideal for virtualization, basic enterprise applications, telecom services, and storage services such as distributed storage, data mining, electronic albums, and videos.


Port

Type

Quantity

Description

Video graphics array (VGA) port

DB15

1

The VGA port is used to connect a terminal, such as a monitor or KVM.

USB port

USB 2.0

2

The USB ports are connected to USB devices.

NOTE:

Before connecting to an external USB device, check that the USB device operates properly. A server may fail if it is connected to an abnormal USB device.



Port

Type

Quantity

Description

VGA port

DB15

1

The VGA port is used to connect a terminal, such as a monitor or KVM.

USB port

USB 3.0

2

The USB ports are connected to USB devices.

NOTE:

Before connecting to an external USB device, check that the USB device operates properly. A server may fail if it is connected to an abnormal USB device.

USB 3.0 is disabled by default. You can enable it on the BIOS as required.

Management network port (Mgmt)

Ethernet port

1

The 1000 Mbit/s Ethernet port is used to manage the server.

Serial port

DB9

1

Three-pin serial port. The default baud rate is 115200 bits/s.

The serial port is used as the system serial port by default. You can set it as the iBMC serial port by using the iBMC command. The port is used for debugging.

Network port

-

-

The port types and quantity vary according to the FlexIO card configured.


Item

Specifications

Form factor

2U rack server

CPU

  • Up to two Intel® Xeon® E5-2600 v3 series CPUs:

    • Number of cores per CPU: 14 cores (2.3 GHz), 12 cores (2.6 GHz), 10 cores (2.6 GHz), 8 cores (2.6 GHz), 6 cores (2.4 GHz), and 4 cores (3.0 GHz)

    • Number of QPI links: 2

    • Maximum transmission speed per QPI link: 9.6 GT/s

    • Maximum L3 cache capacity: 45 MB

  • Up to two Intel® Xeon® E5-2600 v4 series CPUs:

    • Thermal design power (TDP): 120 W

    • Number of cores per CPU: 18 cores (2.1 GHz), 16 cores (2.1 GHz), 14 cores (2.4 GHz), 12 cores (2.2 GHz), 10 cores (2.4 GHz), 8 cores (2.1 GHz), 6 cores (1.7 GHz), and 4 cores (2.6 GHz)

    • Number of QPI links: 2

    • Maximum transmission speed per QPI link: 9.6 GT/s

    • Maximum L3 cache capacity: 45 MB

NOTE:
  • For Intel® Xeon® E5-2600 v4 series processors:

    • The BIOS version must be 3.16 or later.

    • You are advised to upgrade the iBMC and BIOS to the latest mapping versions.

  • The CPUs in one server must have the same BOM number. Use the Intelligent Computing Compatibility Checker to check BOM numbers.

Chipset

Intel C612

RAID support

The RH2288 V3 supports the following models of RAID controller cards:

  • SR320 or SR420:

    • Uses the LSI SAS2208 chip.

    • Supports RAID 0, 1, 10, 5, 50, 6, and 60.

    • Supports a supercapacitor for power failure protection.

  • SR120:

    • Uses the LSI SAS2308 chip.

    • Supports RAID 0, 1, 1E, and 10.

    • Does not support power failure protection.

  • SR130:

    • Uses the LSI SAS3008 chip.

    • Supports RAID 0, 1, 10, and 1E.

    • Does not support power failure protection.

  • SR430C:

    • Uses the LSI SAS3108 chip.

    • Supports RAID 0, 1, 10, 5, 50, 6, and 60.

    • Supports a cache of 1 GB or 2 GB.

    • Supports a supercapacitor for power failure protection.

  • SP435:

    • Uses the PM8060 chip.

    • Supports RAID 0, 1, 10, 5, 50, 6, and 60.

    • Supports a supercapacitor for power failure protection.

  • SR135:

    • Uses the PM8068 chip.

    • Supports RAID 0, 1, 10, and 5.

    • Does not support power failure protection.

These RAID controller cards support RAID level migration and drive roaming.

NOTE:
  • The SP435 (PM8060) controller card is a standard PCIe card, which can be installed in a PCIe slot.

  • Multiple RAID controller cards configuration specifications are provided. For details, see Intelligent Computing Compatibility Checker.

Memory

Up to 16 DDR4 DIMM slots (8 DIMMs per CPU) for installing either RDIMMs or LRDIMMs

  • 16 x 32 GB RDIMMs for two CPUs, with a maximum memory capacity of 512 GB

  • 16 x 128 GB LRDIMMs for two CPUs, with a maximum memory capacity of 2048 GB

  • Maximum memory speed: 2400 MT/s

  • Memory protection technologies: Error Checking and Correction (ECC), memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep

NOTE:

DIMMs of different types (RDIMMs and LRDIMMs) and specifications (such as the capacity, bit width, rank, and height) cannot be installed in one server. That is, all DIMMs in one server must have the same BOM number. To query the BOM numbers of DIMMs, use the Intelligent Computing Compatibility Checker.

Storage

  • Multiple hard disk configuration specifications are provided. For details, see Introduction.

  • Hard disks are hot-swappable.

  • The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID level migration, drive roaming, self-diagnosis, and web-based remote configuration.

  • The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 2 GB cache) to improve hard disk storage performance and ensure user data security.

  • The RAID controller card does not occupy a standard PCIe slot, improving system scalability.

NOTE:
  • If the server is equipped with 12 hard disks at the front, you can install two or four 2.5-inch SAS HDDs, SATA HDDs, and SSDs or 3.5-inch SAS HDDs and SATA HDDs at the rear of the server to expand the local storage capacity.

  • If the server is equipped with 25 hard disks at the front, you can install three 2.5-inch SAS HDDs, SATA HDDs, and SSDs at the rear of the server to expand the local storage capacity.

  • If SATADOM SoftRAID is used when NVMe PCIe SSDs are configured, only the Legacy mode can be selected for the BIOS.

Network port

Six types of FlexIO cards are supported, which provide the following network ports:

  • Two GE electrical ports, supporting NC-SI, Wake on LAN (WOL), and Preboot Execution Environment (PXE)

  • Four GE electrical ports, supporting NC-SI, WOL, and PXE

  • Two 10GE optical ports, supporting NC-SI and PXE

  • Two 10GE electrical ports, supporting NC-SI, WOL, and PXE

  • Two 56G IB optical ports. The FlexIO card does not support NC-SI, WOL, or PXE.

  • One 56G IB optical port. The FlexIO card does not support NC-SI, WOL, or PXE.

PCIe slot

  • The RH2288 V3 provides one PCIe 3.0 x8 slot dedicated for a RAID controller card and five standard PCIe 3.0 x8 slots.

    The specifications for the five standard PCIe slots are described as follows:

    • One full-height full-length standard PCIe 3.0 x16 slot (bus width: PCIe 3.0 x8), one full-height full-length standard PCIe 3.0 x8 slot, and one full-height half-length standard PCIe 3.0 x8 slot on I/O module 2 (Signals of the PCIe slots on I/O module 2 come from CPU 2.)

    • Two half-height half-length standard PCIe 3.0 x8 slots on the mainboard (PCIe slot signals come from CPU 1.)

  • PCIe slots on an I/O module can house a maximum of two Huawei ES3000 V2 SSDs to improve I/O performance for search, cache, and download services.

  • PCIe slots can house K2000 and NVS 315 GPUs.

NOTE:

Specifications of the rear hard disk module:

  • Two 2.5-inch hard disk slots

  • Two 3.5-inch hard disk slots

Specifications of the I/O module:

  • One full-height full-length standard PCIe 3.0 x16 slot (bus width: PCIe 3.0 x8), one full-height full-length standard PCIe 3.0 x8 slot, and one full-height half-length standard PCIe 3.0 x8 slot

  • Two full-height full-length standard PCIe 3.0 x16 slots (bus width of one slot: PCIe 3.0 x8)

  • Two 2.5-inch hard disk slots

  • The fifth-generation SSD cards must be installed in the two slots on a riser card. A server supports a maximum of two fifth-generation SSD cards.

Port

  • Two USB 2.0 ports and one DB15 VGA port on the front panel of the server with up to eight 2.5-inch or ten 3.5-inch hard disks

  • Two USB 3.0 ports, one DB15 VGA port, one DB9 serial port, and one RJ45 system management port on the rear panel

  • One internal USB 3.0 port, one internal dual-SD port, and two internal miniSSDs (SATADOMs) for installing an OS or prebooting an installation program

NOTE:

The internal USB port cannot be used for installing a Windows OS. The server with two internal miniSSDs (SATADOMs) and SoftRAID does not support the installation of a virtualization OS. Use the Intelligent Computing Compatibility Checker to check OSs that can be installed.

Fan module

Four hot-swappable fan modules, allowing one-fan failures

PSU

Two hot-swappable PSUs in redundancy mode:

  • 460 W AC Platinum PSU, supporting 240 V HVDC

  • 750 W AC Platinum PSU, supporting 240 V HVDC

  • 750 W AC Titanium PSU

  • 1200 W PSU, supporting 380 V HVDC

  • 800 W PSU, supporting –48 V DC or –60 V DC

NOTE:

The PSUs in one server must have the same BOM number. Use the Intelligent Computing Compatibility Checker to check BOM numbers.

System management

  • UEFI

  • Huawei iBMC

    • Uses an independent port.

    • Supports Simple Network Management Protocol (SNMP) and Intelligent Platform Management Interface (IPMI).

    • Provides the GUI, virtual KVM, virtual media, Serial Over LAN (SOL), smart power control, remote control, and hardware monitoring features.

  • NC-SI

  • Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios

Security

  • Power-on password

  • Administrator password

  • TPM

  • Chassis-opening logging

  • Front bezel (optional)

    The front bezel is installed on the front panel and comes with a security lock to prevent unauthorized operations on hard disks.

GPU

Integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors.

NOTE:
  • After a dedicated graphics card driver is installed, only Windows Server 2012, Windows Server 2012 R2, Windows Server 2016 can support the resolution of 1920 pixels x 1200 pixels while other OSs only support the maximum resolution supported by the built-in drivers.

  • If the resolution is greater than 1024 x 768, the display effect may be affected.


Item

Specifications

Dimensions (H x W x D)

  • Chassis equipped with 3.5-inch hard disks: 86.1 mm (2U) x 447 mm x 748 mm (3.39 in. x 17.60 in. x 29.45 in.)

  • Chassis equipped with 2.5-inch hard disks: 86.1 mm (2U) x 447 mm x 708 mm (3.39 in. x 17.60 in. x 27.87 in.)

Installation space

The server fits into a universal cabinet that complies with the IEC 297 standard:

  • Width: 19 in.

  • Minimum depth: 1000 mm (39.37 in.)

Requirements for guide rail installation:

  • L-shaped guide rails: apply only to a Huawei cabinet.

  • Adjustable guide rails: apply to a cabinet with a distance of 543.5 mm to 848.5 mm (21.40 in. to 33.41 in.) between the front and rear mounting bars.

  • Holding rails: apply to a cabinet with a distance of 610 mm to 914 mm (24.02 in. to 35.98 in.) between the front and rear mounting bars.

PSU power rating

The PSUs support the following power ratings:

  • 460 W AC PSU: 460 W (input voltage range: 100 V to 240 V AC or 192 V to 288 V DC)

  • 750 W AC PSU: 750 W (input voltage range: 100 V to 240 V AC or 192 V to 288 V DC)

  • 800 W DC PSU: 800 W (input voltage range: –36 V to –75 V DC)

  • 1200 W high-voltage direct current (HVDC) PSU: 1200 W (input voltage range: 260 V to 400 V DC)

Weight in full configuration

Net weight:

  • With eight 2.5-inch hard disks: 27 kg (59.54 lb)

  • With eight 3.5-inch hard disks: 29 kg (63.95 lb)

  • With twelve 3.5-inch hard disks: 30 kg (66.15 lb)

  • With twenty-four 2.5-inch hard disks: 29 kg (63.95 lb)

  • With twenty-five 2.5-inch hard disks: 30 kg (66.15 lb)

Packing material weight: 5 kg (11.03 lb)

Rated input voltage

  • 460 W or 750 W AC PSUs: 100 V to 240 V AC

  • 460 W or 750 W AC PSUs (compatible with 240 V HVDC PSUs): 192 V to 288 V DC

  • 800 W DC PSUs: –36 V to –75 V DC

  • 1200 W high-voltage direct current (HVDC) PSUs: 260 V to 400 V DC

NOTE:

The recommended current specification for the external power circuit breaker connected to the RH2288 V3 is 32 A.

Temperature

  • Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE Class A3 and A4 compliant)

  • Storage temperature: –40°C to +65°C (–40°F to +149°F)

  • Maximum change rate: 20°C/h (36°F/h)

  • Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)

NOTE:
  • The RH2288 V3 can operate at the highest temperature of 35°C (95°F) when it is configured with rear hard disks, and can operate at the highest temperature of 30°C (86°F) when one fan fails.

  • The RH2288 V3 can operate at the highest temperature of 35°C (95°F) when it is configured with Huawei PCIe SSDs.

  • The RH2288 V3 can operate at the highest temperature of 35°C (95°F) when it is configured with GPUs of high power consumption. The system performance may deteriorate when one fan fails.

Heat dissipation

The system draws cool air in from the front, delivers the cool air through the hard disks, fan modules, processors, dual in-line memory modules (DIMMs), and PCIe cards, and then exhausts air from the rear.

Relative humidity (RH, non-condensing)

Operating humidity: 8% to 90%

Storage humidity: 5% to 95%

Maximum change rate: 20% RH/h

Long-term storage humidity: 30% to 69%

Maximum altitude

3048 m (9999.88 ft)

  • For altitudes above 900 m (2952.72 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft) in altitude.

  • At an altitude of over 3000 m (9842.4 ft), only Titanium PSUs can be used.

  • HDDs cannot be used at an altitude of over 3000 m (9842.4 ft).

Acoustic noise

The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

  • Idle:

    • LWAd: 5.1 Bels

    • LpAm: 35.1 dBA

  • Operating:

    • LWAd: 6.1 Bels

    • LpAm: 45.1 dBA

NOTE:

The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.

Corrosive air pollutant

  • Maximum corrosion rate of the copper test piece: 300 Å/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)

  • Maximum corrosion rate of the silver test piece: 200 Å/month

Particulate pollutant

  • The ISO14664-1 Class 8 requirements are met.

    You are advised to ask a professional organization to monitor particulate pollutants in the equipment room.

  • There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.